Vinyl-Insulated (Easy Entry) Double Crimp Locking Spade Terminals
InquiryMaterials: ● Conductor: Copper strip T2/C11000
● Copper sleeve: Copper tubular T2/C11000
● Insulation: PVC
Finished: ● Tin-Plated
Standard: ● ROHS3
Characteristics: ● Heat resistant: -10~75℃
● Flared copper sleeve for easy cable insertion
● The Copper sleeve protection terminal and the cable are fully connected and reliable
● Enable universal used with studs/screws to fix on equipments
● Fixing structure with an open-ended and locking provided a locking feature against lateral stress and can be installed and removed without complete removal of the mounting screw
● According to UL486 requirements
Part No. | Type | Stud (Metric) | Application for Cable Size | Stripped Length(mm) | Dimension(mm) | ||||||||
mm² | A.W.G. | d2 | W | F | L | E | D | d1 | T | ||||
10122302001 | ●LSD1-3.7 | 3.5 | 0.5-1.5 | 22-16 | 7.5-8.0 | 3.7 | 6.4 | 6.5 | 21 | 10.5 | 4.3 | 1.7 | 0.75 |
10122302002 | ●LSD1-4S | 4 | 0.5-1.5 | 22-16 | 7.5-8.0 | 4.3 | 7.2 | 6.5 | 21 | 10.5 | 4.3 | 1.7 | 0.75 |
10122302003 | ●LSD1-4L | 4 | 0.5-1.5 | 22-16 | 7.5-8.0 | 4.3 | 8.1 | 6.5 | 21 | 10.5 | 4.3 | 1.7 | 0.75 |
10122302004 | ●LSD1-5S | 5 | 0.5-1.5 | 22-16 | 7.5-8.0 | 5.3 | 8.1 | 6.5 | 21 | 10.5 | 4.3 | 1.7 | 0.75 |
10122302005 | ●LSD1-5L | 5 | 0.5-1.5 | 22-16 | 7.5-8.0 | 5.3 | 9.5 | 6.5 | 21 | 10.5 | 4.3 | 1.7 | 0.75 |
10122302006 | ●LSD2-3.7 | 3.5 | 1.5-2.5 | 16-14 | 7.5-8.0 | 3.7 | 6 | 6.5 | 21 | 10.5 | 4.8 | 2.3 | 0.8 |
10122302007 | ●LSD2-4 | 4 | 1.5-2.5 | 16-14 | 7.5-8.0 | 4.3 | 7.2 | 6.5 | 21 | 10.5 | 4.8 | 2.3 | 0.8 |
10122302008 | ●LSD2-4L | 4 | 1.5-2.5 | 16-14 | 7.5-8.0 | 4.3 | 8.1 | 6.5 | 21 | 10.5 | 4.8 | 2.3 | 0.8 |
10122302009 | ●LSD2-5S | 5 | 1.5-2.5 | 16-14 | 7.5-8.0 | 5.3 | 8.1 | 6.5 | 21 | 10.5 | 4.8 | 2.3 | 0.8 |
10122302010 | ●LSD2-5 | 5 | 1.5-2.5 | 16-14 | 7.5-8.0 | 5.3 | 9.3 | 6.5 | 21 | 10.5 | 4.8 | 2.3 | 0.8 |
10122302011 | ●LSD5-3.7 | 3.5 | 4-6 | 12-10 | 8.5-9.0 | 3.7 | 8.3 | 7 | 25.2 | 13 | 6.3 | 3.4 | 1 |
10122302012 | ●LSD5-4 | 4 | 4-6 | 12-10 | 8.5-9.0 | 4.3 | 8.3 | 7 | 25.2 | 13 | 6.3 | 3.4 | 1 |
10122302013 | ●LSD5-5 | 5 | 4-6 | 12-10 | 8.5-9.0 | 5.3 | 9 | 7 | 25.2 | 13 | 6.3 | 3.4 | 1 |
Materials: ● Conductor: Copper strip T2/C11000
● Copper sleeve: Copper tubular T2/C11000
● Insulation: PVC
Finished: ● Tin-Plated
Standard: ● ROHS3
Characteristics: ● Heat resistant: -10~75℃
● Flared copper sleeve for easy cable insertion
● The Copper sleeve protection terminal and the cable are fully connected and reliable
● Enable universal used with studs/screws to fix on equipments
● Fixing structure with an open-ended and locking provided a locking feature against lateral stress and can be installed and removed without complete removal of the mounting screw
● According to UL486 requirements