Jiaxing Airic Power Technology Co.,Ltd

+86-573-85829888 sales@airic-terminal.com 中文| En|
   
United States United Kingdom

Products

    Nylon-Insulated (Easy Entry) Double Crimp Flange Spade Terminals

    Materials:          ● Conductor: Copper strip T2/C11000

                             ● Copper sleeve: Copper tubular T2/C11000

                             ● Insulation: Nylon

    Finished:           ● Tin-Plated

    Standard:          ● ROHS3

    Characteristics: ● Heat resistant: -40~105℃

                             ● Flared copper sleeve for easy cable insertion

                             ● The Copper sleeve protection terminal and the cable are fully connected and reliable

                             ● Enable universal used with studs/screws to fix on equipments

                             ● Fixing structure with of an open-ended can be installed and removed without complete removal of the mounting screw

                             ● The flanged ends reduce possibility of terminal separation

                             ● According to UL486 requirements


    p6.jpg

    Inquiry
    1. Parameter
    2. Instructions
    3. Video
    4. 描述

    FSNYD-01.jpg

    Part No.TypeStud
    (Metric)
    Application for Cable SizeStripped Lengthmm)Dimension(mm)
    mm²A.W.G.d2WFLEDAd1T
    10133310001FSNYD1-220.5-1.522-167.5-8.02.26.45.12010.74.41.51.70.75
    10133310002FSNYD1-3.230.5-1.522-167.5-8.03.27.55.12010.74.41.51.70.75
    10133310003FSNYD1-3.2S30.5-1.522-167.5-8.03.26.45.12010.74.41.51.70.75
    10133310004FSNYD1-3.73.50.5-1.522-167.5-8.03.77.55.12010.74.41.51.70.75
    10133310005FSNYD1-3.7S3.50.5-1.522-167.5-8.03.76.45.12010.74.41.51.70.75
    10133310006FSNYD1-3.7L3.50.5-1.522-167.5-8.03.78.57.225.510.74.41.51.70.75
    10133310007FSNYD1-440.5-1.522-167.5-8.04.37.55.12010.74.41.51.70.75
    10133310008FSNYD1-4L40.5-1.522-167.5-8.04.38.57.225.510.74.41.51.70.75
    10133310009FSNYD1-550.5-1.522-167.5-8.05.37.55.12010.74.41.51.70.75
    10133310010FSNYD1-5L50.5-1.522-167.5-8.05.38.57.225.510.74.41.51.70.75
    10133310011FSNYD2-3.73.51.5-2.516-147.5-8.03.77.55.220.510.751.52.30.8
    10133310012FSNYD2-3.7L3.51.5-2.516-147.5-8.03.78.57.22410.751.52.30.8
    10133310013FSNYD2-441.5-2.516-147.5-8.04.37.55.220.510.751.52.30.8
    10133310014FSNYD2-4M41.5-2.516-147.5-8.04.386.824.510.751.52.30.8
    10133310015FSNYD2-4L41.5-2.516-147.5-8.04.38.57.22410.751.52.30.8
    10133310016FSNYD2-551.5-2.516-147.5-8.05.37.55.220.510.751.52.30.8
    10133310017FSNYD2-5L51.5-2.516-147.5-8.05.38.57.22410.751.52.30.8
    10133310018FSNYD5-3.73.54-612-108.5-9.03.78.57.52712.771.53.41
    10133310019FSNYD5-3.7S3.54-612-108.5-9.03.77.66.225.512.771.53.41
    10133310020FSNYD5-444-612-108.5-9.04.38.57.52712.771.53.41
    10133310021FSNYD5-4S44-612-108.5-9.04.37.66.225.512.771.53.41
    10133310022FSNYD5-554-612-108.5-9.05.38.57.52712.771.53.41
    10133310023FSNYD5-5S54-612-108.5-9.05.37.66.225.512.771.53.41



    p6.jpg

    p6.jpg

    p6.jpg

    Materials:          ● Conductor: Copper strip T2/C11000

                             ● Copper sleeve: Copper tubular T2/C11000

                             ● Insulation: Nylon

    Finished:           ● Tin-Plated

    Standard:          ● ROHS3

    Characteristics: ● Heat resistant: -40~105℃

                             ● Flared copper sleeve for easy cable insertion

                             ● The Copper sleeve protection terminal and the cable are fully connected and reliable

                             ● Enable universal used with studs/screws to fix on equipments

                             ● Fixing structure with of an open-ended can be installed and removed without complete removal of the mounting screw

                             ● The flanged ends reduce possibility of terminal separation

                             ● According to UL486 requirements


    p6.jpg